home
***
CD-ROM
|
disk
|
FTP
|
other
***
search
/
Penthouse Guide to Cybersex
/
Penthouse Guide to Cybersex.iso
/
pc
/
psi
/
win
/
netmanag.mi_
/
netmanag.mi
Wrap
Text File
|
1994-12-24
|
11KB
|
450 lines
-- NetManage Private MIB definitions
--
-- MIB for release 3.10 of SNMPD
--
-- Copyright 1992-1993 NetManage, Inc. All Rights Reserved.
-- Reproduction of this document is authorized on
-- condition that the foregoing notice is included.
--
-- This SNMP MIB Specification contains NetManage's confidential
-- and proprietary intellectual property.
-- NetManage, Inc. retains all title and ownership in the
-- Specification, including any revisions.
--
-- It is NetManage's intent to encourage the widespread use of this
-- specification in connection with the management of desktops
-- using the Chameleon, Chameleon/NFS or NEWT. NetManage grants
-- vendors, end-users, and other interested parties a non-exclusive
-- license to use this Specification in connection with the
-- management of NetManage's products.
--
-- This Specification is supplied "AS IS", and NetManage makes no
-- warranty, either express or implied, as to the use, operation,
-- condition, or performance of the Specification.
--
NETMANAGE-MIB {
iso org(3) dod(6) internet(1) private(4) enterprises(1) 233
}
DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Gauge, TimeTicks, IpAddress FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC1212;
-- Categories
netmanage OBJECT IDENTIFIER ::= { enterprises 233 }
snmpd OBJECT IDENTIFIER ::= { netmanage 1 }
workstation OBJECT IDENTIFIER ::= { netmanage 2 }
dos OBJECT IDENTIFIER ::= { netmanage 3 }
windows OBJECT IDENTIFIER ::= { netmanage 4 }
-- NetManage Object Types
-- SNMPD Group
-- SNMPD Agent table
agentTable OBJECT-TYPE
SYNTAX SEQUENCE OF AgentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table holds the list of all
agents registered with the deamon"
::= { snmpd 1 }
agentEntry OBJECT-TYPE
SYNTAX AgentEntry
ACCESS not-accessible
STATUS mandatory
INDEX { agentEnterprise }
::= { agentTable 1 }
AgentEntry ::= SEQUENCE {
agentEnterprise
OBJECT IDENTIFIER,
agentWindow
INTEGER,
agentDescription
DisplayString
}
agentEnterprise OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The enterprise-ID (sub-tree) for which the
agent is registered"
::= { agentEntry 1 }
agentWindow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The window handle of the agent's process"
::= { agentEntry 2 }
agentDescription OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The agent's description"
::= { agentEntry 3 }
-- Workstation Group
wsCPU OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The workstation CPU type (e.g.,80386)"
::= { workstation 1 }
wsComputerType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The workstation Computer Type (e.g., PC/AT)"
::= { workstation 2 }
wsModel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The computer's model number"
::= { workstation 3 }
wsSubmodel OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The computer's submodel number"
::= { workstation 4 }
wsBiosVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Bios version"
::= { workstation 5 }
wsOS OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operating system name (e.g., MS-DOS)"
::= { workstation 6 }
wsOSMajVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operating system major version
number (e.g., 5 for DOS 5.0)"
::= { workstation 7 }
wsOSMinVersion OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The operating system minor version
number (e.g., 0 for DOS 5.0)"
::= { workstation 8 }
wsNDISTable OBJECT-TYPE
SYNTAX SEQUENCE OF WsNDISEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table holds objects related to network
adapter cards in your computer: one entry
per each adapter"
::= { workstation 9 }
wsNDISEntry OBJECT-TYPE
SYNTAX WsNDISEntry
ACCESS not-accessible
STATUS mandatory
INDEX { wsPermPhysAddr }
::= { wsNDISTable 1 }
WsNDISEntry ::= SEQUENCE {
wsPermPhysAddr
PhysAddress,
wsCurrPhysAddr
PhysAddress,
wsDescription
DisplayString,
wsModuleName
DisplayString,
wsMACType
DisplayString,
wsIEEECode
OCTET STRING,
wsIRQ
INTEGER,
wsFrameSize
INTEGER,
wsTXCapacity
INTEGER,
wsDriverType
INTEGER
}
wsPermPhysAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The permanent address of the adapter
unique for each card"
::= { wsNDISEntry 1 }
wsCurrPhysAddr OBJECT-TYPE
SYNTAX PhysAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current address assigned to the adapter
(not always equal to the permanent address. Some
communications packages, such as Decnet, changes it)"
::= { wsNDISEntry 2 }
wsDescription OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Textual description of the adapter type"
::= { wsNDISEntry 3 }
wsModuleName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the module name (in PROTOCOL.INI)"
::= { wsNDISEntry 4 }
wsMACType OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC type used by the adapter"
::= { wsNDISEntry 5 }
wsIEEECode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"IEEE code assigned to
the manufacturer of the adapter"
::= { wsNDISEntry 6 }
wsIRQ OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interrupt line used by the adapter"
::= { wsNDISEntry 7 }
wsFrameSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Frame Size used by the adapter"
::= { wsNDISEntry 8 }
wsTXCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Transmit Buffer capacity of the adapter"
::= { wsNDISEntry 9 }
wsMathCoprocessor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Returns 1 if math co-processor exists,
0 otherwise"
::= { workstation 10 }
wsFloppyDrives OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of floppy drives
defined for the workstation"
::= { workstation 11 }
wsRS232Ports OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of serial ports defined
for the workstation"
::= { workstation 12 }
-- DOS Group
dosCurrentDrive OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current DOS Drive in use at your machine
with 1=A, 2=B, etc."
::= { dos 1 }
dosMemorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DOS base memory size in
K-bytes (typically 640)"
::= { dos 2 }
-- Windows Group
winVersion OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Window's version number of the PC"
::= { windows 1 }
winMemoryAbove OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of memory (in bytes) available
above the EMS bankline ( refer to Windows Guide
to Programming for more information)"
::= { windows 2 }
winMemoryBelow OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of memory (in bytes) available
below the EMS bankline ( refer to Windows Guide
to Programming for more information)"
::= { windows 3 }
winFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Window's configuration flags on
the PC. ( refer to Windows Guide for Programming
for more information)"
::= { windows 4 }
-- Window's Task table
winTaskTable OBJECT-TYPE
SYNTAX SEQUENCE OF WinTaskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table lists all the software applications
(tasks) currently running on the PC"
INDEX { winHandle }
::= { windows 5 }
winTaskEntry OBJECT-TYPE
SYNTAX WinTaskEntry
ACCESS not-accessible
STATUS mandatory
::= { winTaskTable 1 }
WinTaskEntry ::= SEQUENCE {
winHandle
INTEGER,
winStyle
INTEGER,
winClass
DisplayString,
winTitle
DisplayString,
winModule
DisplayString
}
winHandle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The window handle of the
task ( meaningful only to programmers)"
::= { winTaskEntry 1 }
winStyle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The window style (a bit mask of
different attributes meaningful only to
programmers)"
::= { winTaskEntry 2 }
winClass OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the class
of the task"
::= { winTaskEntry 3 }
winTitle OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The title(name) of the task
(e.g., 'Program Manager', 'ping-UNIX', etc.)"
::= { winTaskEntry 4 }
winModule OBJECT-TYPE
SYNTAX DisplayString(SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The task module (typically the command that
started it. e.g., c:\netmanag\ping.exe)"
::= { winTaskEntry 5 }
END